25.03.2017 17:32:35 uTracer3, GUI V3.11 Pentode Quick Test ECF82_6GN8 #140 Test conditions: Va : 170 (V) Swing +/- 17 V (10%) Vs : 170 (V) Swing +/- 17 V (10%) Vg : -2 (V) Swing +/- 0,2 V (10%) Test results: Ia : 10,46 (mA) 105 % of nominal 10 (mA) Gma : 4,7 (mA/V) 76 % of nominal 6,2 (mA/V) Gma = dIa/dVg Ra : 308,28 (kohm) 77 % of nominal 400 (kohm) Ra = dVa/dIa mu1 : 1450 (-) 483 % of nominal 300 (-) mu1 = Gma*Ra Gm1 : 139 (uA/V) Gm1 = dIa/dVs Is : 3,54 (mA) 126 % of nominal 2,8 (mA) Gms : 1,69 (mA/V) Gma = dIs/dVg Rs : 19,65 (kohm) Rs = dVs/dIs mu2 : 33 (-) mu2 = Gms*Rs Gm2 : -2 (uA/V) Gm2 = dIs/dVa