24.03.2017 19:16:08 uTracer3, GUI V3.11 Pentode Quick Test ECF80 6BL8 #101 Test conditions: Va : 170 (V) Swing +/- 17 V (10%) Vs : 170 (V) Swing +/- 17 V (10%) Vg : -2 (V) Swing +/- 0,2 V (10%) Test results: Ia : 7,58 (mA) 76 % of nominal 10 (mA) Gma : 5,33 (mA/V) 86 % of nominal 6,2 (mA/V) Gma = dIa/dVg Ra : 608,57 (kohm) 152 % of nominal 400 (kohm) Ra = dVa/dIa mu1 : 3246 (-) >>> % of nominal 300 (-) mu1 = Gma*Ra Gm1 : 120 (uA/V) Gm1 = dIa/dVs Is : 1,91 (mA) 68 % of nominal 2,8 (mA) Gms : 1,38 (mA/V) Gma = dIs/dVg Rs : 30,06 (kohm) Rs = dVs/dIs mu2 : 41 (-) mu2 = Gms*Rs Gm2 : 0 (uA/V) Gm2 = dIs/dVa